Product Specification |
Cisco XR 12000 and 12000 Series 16-Slot Chassis |
Cisco XR 12000 and 12000 Series 10-Slot Chassis |
Cisco XR 12000 and 12000 Series 6-Slot Chassis |
Cisco XR 12000 and 12000 Series 4-Slot Chassis |
Slot capacity |
16 slots |
10 slots |
6 slots |
4 slots |
Aggregate switching capacity |
Cisco 12016: 80 Gbps
Cisco 12416: 320 Gbps
Cisco 12816: 1280 Gbps |
Cisco 12010: 50 Gbps
Cisco 12410: 200 Gbps
Cisco12810: 800 Gbps |
Cisco 12006: 30 Gbps
Cisco 12406: 120 Gbps |
Cisco 12404: 80 Gbps |
Full-duplex throughput per slot |
Cisco 12016: 2.5 Gbps/slot
Cisco 12416: 10 Gbps/slot
Cisco 12816: 40 Gbps/slot |
Cisco 12010: 2.5 Gbps/slot
Cisco 12410: 10 Gbps/slot
Cisco 12810: 40 Gbps/slot |
Cisco 12006: 2.5 Gbps/slot
Cisco 12406: 10 Gbps/slot |
Cisco 12404: 10 Gbps/slot |
Physical |
Chassis height
71.5 in. (181.6 cm)
72.5 in. (184.2 cm)1
Chassis width
17.25 in. (43.8 cm)
18.75 in. (47.6 cm)2
Chassis depth
22.0 in. (55.9 cm)
24.0 in. (61.0 cm)3
Weight
140 lb (64 kg)4
390 lb (177 kg)5 |
Chassis height
37.5 in. (95.25 cm)
Chassis width
19 in. (48.26 cm)
Chassis depth
22.0 in. (55.9 cm)
24.0 in. (61.0 cm) weight
125 lb (57 kg)
275 lb (125 kg) |
Chassis height
18.5 in. (47.0 cm)
Chassis width
17.3 in. (43.9 cm)
18.9 in. (48.0 cm)
Chassis depth
28.0 in. (71.1 cm)
Weight
140 lb (64 kg)
205 lb (94 kg) |
Chassis height
8.75 in. (22.23 cm)
Chassis width
17.38 in. (44.15 cm)
18.9 in. (48.01 cm)
Chassis depth
27.5 in. (69.85 cm)
Weight
73 lb (33.18 kg)
103 lb (46.82 kg) |
Chassis per rack |
One |
Two |
Four |
Eight |
Electrical specifications for the AC input power |
Total AC input power
1 |
4651 VA (max) per chassis |
2790 VA (max) per chassis |
Low Line 1708 VA (max)
High Line 1950 VA (max) per chassis |
1341 VA (max) per chassis |
Rated input voltage
2 |
200-240 VAC nominal (range: 180-264 VAC) |
200-240 VAC nominal (range: 180-264 VAC) |
100-120 VAC (Low Line) 200-240 VAC (High Line) nominal (range: 85-264 VAC) |
100-120 VAC or 200-240 VAC nominal (range: 85-264 VAC) |
Rated input line frequency |
50-60 Hz nominal (range: 47-63 Hz) |
50-60 Hz nominal (range: 47-63 Hz) |
50-60 Hz nominal (range: 47-63 Hz) |
50-60 Hz nominal (range: 47-63 Hz) |
Input current rating
(For any line cord) |
10.3A maximum @ 240 VAC |
11.6A maximum @ 240 VAC |
17.2A (max) @ 100 VAC
10A (max) @ 200 VAC |
6A maximum @ 240 VAC |
Source AC service requirement |
20A North America; 16A international |
20A North America; 16A international |
20A North America; 16A international |
20A North America; 16A international |
Electrical specifications for DC input power |
Total DC input power |
4212 W (max) |
2430 W (max) |
1630 W (max) |
1280 W (max) |
Rated input voltage |
-48 VDC nominal in North America |
-48 VDC nominal in North America |
-48 VDC nominal in North America |
-48 VDC nominal in North America |
-60 VDC nominal in the European community (range: -40.5 to -75 VDC) |
-60 VDC nominal in the European community (range: -40.5 to -75 VDC |
-60 VDC nominal in the European community (range: -40.5 to -75 VDC |
-60 VDC nominal in the European community (range: -40.5 to -75 VDC |
Input current rating
For any DC input pair |
52A maximum @ 40.5 VDC
3 |
60A maximum @ 40.5 VDC |
45A maximum @ 40.5 VDC |
35A maximum @ 40.5 VDC |
Source DC service requirement |
60A |
60A |
60A |
60A |
Environmental conditions |
Temperature |
Operating: 32 to 104°F (0 to 40°C)
Nonoperating: -4 to 149°F (-20 to 65°C) |
Operating: 32 to 104°F (0 to 40°C)
Nonoperating: -4 to 149°F (-20 to 65°C) |
Operating: 32 to 104°F (0 to 40°C)
Nonoperating: -4 to 149°F (-20 to 65°C) |
Operating: 32 to 104°F (0 to 40°C)
Nonoperating: -40 to 158°F (-40 to 70°C) |
Humidity |
Operating: 10-90% noncondensing
Nonoperating: 5-95% noncondensing |
Operating: 10-90% noncondensing
Nonoperating: 5-95% noncondensing |
Operating: 10-90% noncondensing
Nonoperating: 5-95% noncondensing |
Operating: 5-90% noncondensing
Nonoperating: 5-95% noncondensing |
Altitude |
Operating: 0-10,000 ft. (0-3000m)
Nonoperating: 0-15,000 ft. (0-4570m) |
Operating: 0-10,000 ft. (0-3000m)
Nonoperating: 0-15,000 ft. (0-4570m) |
Operating: 0-10,000 ft. (0-3000m)
Nonoperating: 0-15,000 ft. (0-4570m) |
Operating: 0-14,000 ft. (0-4267m)
Nonoperating: 0-16,000 ft. (0-4877m) |
Heat dissipation |
DC (max): 4212 VA @ 14372 Btu/hr
AC (max):4651 VA @ 15870 Btu/hr |
DC (max): 2430 VA @ 8291 Btu/hr
AC (max):2790 VA @ 9519 Btu/hr |
DC (max): 1630 VA @ 5562 Btu/hr
low line AC (max): 1708 VA @ 5828 Btu/hr
high line AC (max): 1950 VA @ 6654 Btu/hr |
DC (max): 1280 VA @ 4367 Btu/hr
AC (max): 1341 VA @ 4575 Btu/hr |
Acoustic noise |
70 dBa maximum |
70 dBa maximum |
70 dBa maximum |
70 dBa maximum |
Shock |
Operating (halfsine): 21 in./sec (0.53m/sec)
Nonoperating (trapezoidal pulse): 20g, 52 in./sec (1.32 m/sec) |
Operating (halfsine): 21 in./sec (0.53m/sec)
Nonoperating (trapezoidal pulse): 20g, 52 in./sec (1.32 m/sec) |
Operating (halfsine): 21 in./sec (0.53m/sec)
Nonoperating (trapezoidal pulse): 20g, 52 in./sec (1.32 m/sec) |
Operating (halfsine): 5g (11 m/sec)
Nonoperating (trapezoidal pulse): 15g (11 m/sec) |
Vibration |
Operating: 0.35 grms
4 from 3 to 500 Hz
Nonoperating: 1.0 grms from 3 to 500 Hz |
Operating: 0.35 grms from 3 to 500 Hz
Nonoperating: 1.0 grms from 3 to 500 Hz |
Operating: 0.35 grms from 3 to 500 Hz
Nonoperating: 1.0 grms from 3 to 500 Hz |
Operating (sinusoidal): 3-500 Hz @ 0.15 gpk (random): 2.5-200 Hz @ 0.33 grms
Storage (sinusoidal): 10-500 Hz @ 0.8 gpk (random): 2.5-200 Hz @ 1.05 grms |
Hardware components (per base system) |
• 4 DC power supplies, or 3 AC supplies, or 4 AC power supplies
• 1 performance router processor
• 16 line-card slots with 15 line cards and 1 route processor or 14 line cards and 2 route processors (1:1 redundant)
• 3 switch fabric cards (SFCs)
• 2 clock scheduler cards (CSCs)
• 2 alarm cards
• Air filters
• 2 blower assemblies
• 2 cable-management trays
• Country-specific power cords |
• 2 DC power supplies or 2 AC supplies
• 1 performance router processor
• 10 line-card slots with 9 line cards and 1 route processor or 8 line cards and 2 route processors (1:1 redundant)
• 5 SFCs
• 2 CSCs
• 1 alarm card
• Air filter
• 1 blower assembly
• 1 cable-management tray
• Country-specific power cords |
• 2 DC power supplies or 2 AC supplies
• 1 performance router processor
• 6 line-card slots with 5 line cards and 1 route processor or 4 line cards and 2 route processors (1:1 redundant)
• 3 SFCs
• 2 CSCs
• 1 alarm card
• Air filter
• 1 blower assembly
• 1 cable-management tray
• Country-specific power cords |
• 2 DC power supplies or 2 AC supplies
• 1 performance router processor
• 4 line-card slots with 3 line cards and 1 route processor or 2 line cards and 2 route processors (1:1 redundant)
• 1 consolidated switch fabric, clock scheduler, and alarm card
• Air filter
• 1 blower assembly
• 1 cable-management tray
• Country-specific power cords |
Software components (per base system) |
• Cisco IOS XR or Cisco IOS Software Operating System
• Cisco Express Forwarding for distributed packet forwarding |
• Cisco IOS XR or Cisco IOS Software Operating System
• Cisco Express Forwarding for distributed packet forwarding |
• Cisco IOS XR or Cisco IOS Software Operating System
• Cisco Express Forwarding for distributed packet forwarding |
• Cisco IOS XR or Cisco IOS Software Operating System
• Cisco Express Forwarding for distributed packet forwarding |
Compatibility |
Cisco 12800: Line cards that support 2.5-, 10-, or 20-Gbps capability
Cisco 12400: Line cards that support 2.5- or 10-Gbps capability
Cisco 12000: Line cards that support 2.5-Gbps capability |
Protocols |
IPv4, MPLS, Border Gateway Protocol Version 4 (BGPv4), Intermediate System-to-Intermediate System (IS-IS), Open Shortest Path First Version 2.0 (OSPFv2.0), Routing Information Protocol Version 2 (RIPv2), Internet Group Management Protocol (IGMP), Distance Vector Multicast Routing Protocol (DVMRP), and Protocol Independent Multicast dense mode/sparse mode (PIM DX/SX) |
Connectivity |
Packet over SONET/SDH (POS), Ethernet, ATM, copper (DS-3/E3), Channelized (CT3, ChOC-3/CHSTM1, ChOC-12/CHSTM4, ChOC-48/CHSTM16); see Cisco IOS XR Software release notes for specific connectivity support on the Cisco XR 12000 Series |
Reliability |
System redundancy:
• Fabric card redundancy 4:1
• CSC redundancy 1:1
• Power supply redundancy (1:1 for DC; AC is load balancing)
• Blower redundancy 1:1
• Route processor redundancy 1:1
• Alarm card redundancy 1:1
• Dual homing through line cards
• Supports automatic protection switching (APS) ASICs
Mean time between failure (MTBF):
• CSC = 240,078 hr
• SFC = 276,062 hr |
Management interfaces |
Cisco XR 12000 and Cisco 12000 Series Performance Route Processor (PRP) supports two serial ports (console and auxiliary) and one 10/100 Ethernet port |
Indicators and Interfaces |
Visual alarms for critical, major, and minor states on CSCs, SFCs, and on or error condition for system alarm boards |
Compliance |
Safety certification:
• UL 1950
• CSA-22.2 No. 950
• EN60950
• IEC 60950 CB Scheme
• ACA TS001
• AS/NZS 3260
• EN60825\IEC60825 laser safety
• FDA-Code of Federal Regulations (USA) laser safety
Electromagnetic compliance (emissions):
• FCC Class A
• ICES-003 Class A
• EN55022 Class B (to 1 GHz)
• VCCI Class B (to 1 GHz)
• AS/NZS 3548 Class B
• MSZEN55022 Class A
• CISPR 22 Class B (up to 1 GHz)
• BSMI Class A
Immunity:
• IEC-1000-4-2 ESD (8kV contact, 15kV air)
• IEC-1000-4-3 Radiated immunity (10V/m)
• IEC-1000-4-4 EFT (2kV power port, 1kV signal port)
• IEC-1000-4-5 Surge AC port (4kV CM, 2kV DM)
• IEC-1000-4-5 Surge signal port (2kV CM, 1kV DM)
• IEC-1000-4-5 Surge DC port (0.5kV CM, 0.5kV DM)
• IEC-1000-4-6 Low frequency conductive immunity (10V)
• IEC-1000-4-11 Voltage dips and sags
• IEC-1000-3-2 Power line harmonics |
Approval agencies |
Network Equipment Building Standards (NEBS)
• Designed to be NEBS-compliant
ETSI
• EN300386
• ETS 300132-2 |