Beskrivning

Rack PDU 2G, Switched Plus, ZeroU, 32A, 230V, (21) C13 & (3) C19


APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

Output

  • Nominal Output Voltage 230V
  • Maximum Total Current Draw per Phase 32A
  • Output Connections (21) IEC 320 C13
  • (3) IEC 320 C19
  • Overload Protection Yes

Input

  • Nominal Input Voltage 200V,208V,230V
  • Input Frequency 50/60 Hz
  • Input Connections IEC 309 32A 2P+E
  • Cord Length 3 meters
  • Number of Power Cords 1
  • Acceptable Input Voltage 220-240 VAC
  • Maximum Line Current per phase 32A
  • Maximum Input Current per phase 32A

Physical

  • Net Weight 8.23 KG
  • Maximum Height 1829.00 mm
  • Maximum Width 56.00 mm
  • Maximum Depth 51.00 mm
  • Shipping Weight 10.50 KG
  • Shipping Height 2038.00 mm
  • Shipping Width 162.00 mm
  • Shipping Depth 118.00 mm
  • Color Black
  • Units per Pallet 42.00

Environmental

  • Operating Environment -5 - 45 °C
  • Operating Relative Humidity 5 - 95%
  • Operating Elevation 0-3000 meters
  • Storage Temperature -25 - 65 °C
  • Storage Relative Humidity 5 - 95%
  • Storage Elevation 0-15000 meters

Conformance

  • Regulatory Approvals EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3-3,VDE
  • Standard Warranty 2 years repair or replace
  • Environmental Compliance RoHS,REACH: Contains No SVHCs,Contains Lithium Battery

Features

Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

Features & Benefits

Availability

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Agility

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Även om vi gör vårt bästa för att ge relevant information, så är bilderna bara till för att ge ett generellt intryck, och själva varan behöver nödvändigtvis inte se ut precis som på bilden. Om det är skillnader mellan produktöverskrift, beskrivning och bild, så är det produktöverskriften som gäller. (tex. Pc:n kommer inte nödvändigtvis med monitor även om bilden visar det) Om något är oklart skicka en e-post till oss före du beställer! Vi förbehåller oss för tryckfel, ändringar av priser och specifikationer utan varsel.